lr_input
prefix pwscf
Sets the prefix for generated and read files. The files
generated by the ground state pw.x run should have this
same prefix.
outdir ./
The directory that contains the run critical files, which
include the files generated by ground state pw.x run.
wfcdir unset
The directory where the scratch files will be written and read.
Restart related files are always written to outdir.
restart .false.
When set to .true., turbo lanczos.x will attempt to restart
from a previous interrupted calculation. (see restart_step
variable).
restart_step itermax
The code writes restart files every restart step iterations.
Restart files are automatically written at the end of itermax
Lanczos steps.
lr verbosity 1
This integer variable controls the amount of information written
in standard output.
disk_io default
Fine control of disk usage. Currently only 'reduced' is
supported where no restart files are written, apart from the
'default' mode.
lr_control
itermax 500
Number of iterations to be performed.
ipol 1
An integer variable that determines which element of the
dynamical polarizabil- ity will be computed: 1 → αxx(ω),
2 → αyy(ω), and 3 → αzz(ω). When set to 4, three Lanczos chains
are sequentially performed and the full polarizability tensor
and the absorption coefficient are computed.
nipol 1 if ipol < 4; 3 if ipol=4
Determines the number of zeta coefficients to be calculated for
a given polarization direction.
ltammd .false.
When set to .true. the Tamm-Dancoff approximation is used in
constructing the Liouvillian.
no_hxc .false.
When set to .true. the change in the internal field (Hartree and
exchange-correlation) is ignored in the calculation, resulting
in an independent electron approximation.
charge_response 0
When set to 1, the code computes the response of the charge
density and writes it into a file format determined by the
variable plot type. Setting charge response to 1 makes the
presence of the card lr post mandatory.
lr_post
omeg 0.0
The response of the charge density is calculated for this
transition energy (in Rydberg units)
epsil 0.0
The broadening/damping term (in Rydberg units).
beta gamma_z_prefix pwscf
The prefix of the file where the beta gamma zeta coefficients
from the first calculation can be set manually using this
parameter. The file outdir/beta gamma z prefix.beta gamma z.x
(where x=1-3) must exist.
w_T_npol 1
Number of polarization directions considered in the previous
calculation. It must be set to 3 if in the previous calculation
ipol=4, it must be set to 1 otherwise.
plot type 1
An integer variable that determines the format of the file
containing the charge density response. 1: A file containing
the x y z grid coordinates and the corre- sponding value of the
density is produced 2: The density response is written in
Xcrysden format 3: The density response is written in the
gaussian cube format