abinit/tests/v2/Input/t92.abi

88 lines
1.8 KiB
Plaintext

# Li compressed simple cubic, metallic.
# Large smearing width
ndtset 4
# Defaults for phonon calculations
nqpt 1
rfphon 1
rfdir 0 1 0
#DATASET 1 : SC run with 4 kpoints
getwfk1 0
nqpt1 0
rfphon1 0
kptopt1 1
tolwfr1 1.0d-22
#DATASET 2 : RF at Gamma
qpt2 0.0d0 0.0d0 0.0d0
rfphon2 1
toldfe2 1.0d-10
#DATASET 3 : RF at 1/2 0 0
qpt3 0.5d0 0.0d0 0.0d0
rfphon3 1
toldfe3 1.0d-10
#DATASET 4 : RF at 1/4 0 0
qpt4 0.25d0 0.0d0 0.0d0
rfphon4 1
toldfe4 1.0d-10
#Backwards compatibility
asr 0 # The default value 1 is preferable, this is only to keep backward compatibility for the automatic tests
chneut 0 # The default value 1 is preferable, this is only to keep backward compatibility for the automatic tests
#Common data
acell 3*4.90
ntypat 1
znucl 3.0
natom 1
typat 1
xred 0.0 0.0 0.0
nstep 20
ecut 5.0
nband 3
nbdbuf 1
getwfk 1
kptopt 3
occopt 7
tsmear 0.04
ngkpt 4 4 4
shiftk
0.5 0.5 0.5
pp_dirpath "$ABI_PSPDIR"
pseudos "PseudosTM_pwteter/3li.pspnc"
#%%<BEGIN TEST_INFO>
#%% [setup]
#%% executable = abinit
#%% [files]
#%% files_to_test =
#%% t92.abo, tolnlines = 2, tolabs = 1.10e-09, tolrel = 2.000e-04, fld_options =
#%% [paral_info]
#%% max_nprocs = 4
#%% [extra_info]
#%% keywords = NC, DFPT
#%% authors = Unknown
#%% description =
#%% Li, simple cubic, to test accurately RF in the metallic case.
#%% With non-linear XC core correction.
#%% The total energy of the 1-atom cell is -.29350020247929 Ha
#%% The 2DTE with respect to a q(0 0 0) phonon is 1.557063518d-7 .
#%% The 2DTE with respect to a transverse q(1/2 0 0) phonon
#%% is -0.1426599618 Ha. The 2DTE with respect to a transverse
#%% q(1/4 0 0) phonon is -0.6978404630E-01 Ha.
#%%<END TEST_INFO>