76 lines
2.5 KiB
Bash
Executable File
76 lines
2.5 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
# IMPORTANT! availability zone placement MATTERS for simulation performance.
|
|
# Usually, you will not be able to get 32 nodes in one availability zone,
|
|
# but frequently you will be able to get 16. The way the manager currently
|
|
# terminates nodes is based on their sorted ip address, which may means you
|
|
# end up killing some from different avail zones, even though it would be
|
|
# ideal to completely remove nodes from "extra" availability zones.
|
|
#
|
|
# Until this is fixed in the manager, you should run this script separately to:
|
|
# 1) get the 256 node result by commenting out the rest of the calls to loopfunc
|
|
# 2) terminate your run farm, then launch a new one (where all 16 hosts +
|
|
# switches will likely be in the same availability zone) that supports only 128
|
|
# nodes and below, then run from there, decreasing scale.
|
|
|
|
# run the simperf SCALE poweroff test using the manager. optionally passing "withlaunch" will also
|
|
# automatically launch the appropriate runfarm
|
|
#
|
|
# the runfarm WILL NOT be terminated upon completion
|
|
|
|
trap "exit" INT
|
|
set -e
|
|
set -o pipefail
|
|
|
|
if [ "$1" == "withlaunch" ]; then
|
|
firesim launchrunfarm -c workloads/simperf-test-scale-supernode-config.yaml
|
|
fi
|
|
|
|
ORIGDIR=$(pwd)
|
|
|
|
cd ../results-workload
|
|
|
|
# create the aggregate results directory
|
|
resultsdir=$(date +"%Y-%m-%d--%H-%M-%S")-simperf-test-scale-supernode-aggregate
|
|
mkdir $resultsdir
|
|
|
|
# make sure we don't get the same name as one of the manager produced results
|
|
# directories
|
|
sleep 2
|
|
|
|
loopfunc () {
|
|
echo "RUNNING supernode_example_$1config"
|
|
# arg 1 is num nodes
|
|
# arg 2 is num f116xlarges to kill AFTERWARDS
|
|
# arg 3 is num m416xlarges to kill AFTERWARDS
|
|
firesim infrasetup -c workloads/simperf-test-scale-supernode-config.yaml --overrideconfigdata "target_config topology supernode_example_$1config"
|
|
firesim runworkload -c workloads/simperf-test-scale-supernode-config.yaml --overrideconfigdata "target_config topology supernode_example_$1config"
|
|
# rename the output directory with the ping latency
|
|
files=(*simperf-test-scale*)
|
|
originalfilename=${files[-1]}
|
|
mv $originalfilename $resultsdir/$1
|
|
|
|
firesim terminaterunfarm -c workloads/simperf-test-scale-supernode-config.yaml --terminatesomef116 $2 --terminatesomem416 $3 --forceterminate
|
|
|
|
}
|
|
|
|
loopfunc 1024 16 2
|
|
|
|
loopfunc 512 8 2
|
|
|
|
loopfunc 256 4 0
|
|
|
|
loopfunc 128 2 0
|
|
|
|
loopfunc 64 1 1
|
|
|
|
loopfunc 32 0 0
|
|
|
|
loopfunc 16 0 0
|
|
|
|
loopfunc 8 0 0
|
|
|
|
loopfunc 4 1 0
|
|
|
|
python3 $ORIGDIR/simperf-test-scale/simperf-test-scale-results.py $(pwd)/$resultsdir
|