forked from xtdrone/XTDrone
108 lines
3.5 KiB
C++
108 lines
3.5 KiB
C++
///////////////////////////////////////////////////////////////////////////////
|
|
// this program is just a little test to make sure the laser is working.
|
|
// it's mostly just to familiarize myself with the sicktoolbox library.
|
|
// it's heavily lifted from the sicktoolbox lms_simple_app program.
|
|
//
|
|
// Copyright (C) 2008, Morgan Quigley
|
|
//
|
|
// I am distributing this code under the BSD license:
|
|
//
|
|
// Redistribution and use in source and binary forms, with or without
|
|
// modification, are permitted provided that the following conditions are met:
|
|
// * Redistributions of source code must retain the above copyright notice,
|
|
// this list of conditions and the following disclaimer.
|
|
// * Redistributions in binary form must reproduce the above copyright
|
|
// notice, this list of conditions and the following disclaimer in the
|
|
// documentation and/or other materials provided with the distribution.
|
|
// * Neither the name of Stanford University nor the names of its
|
|
// contributors may be used to endorse or promote products derived from
|
|
// this software without specific prior written permission.
|
|
//
|
|
// THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
|
|
// AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
// IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
// ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
|
|
// LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
|
|
// CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
|
|
// SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
|
// INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
|
|
// CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
|
|
// ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
|
|
// POSSIBILITY OF SUCH DAMAGE.
|
|
|
|
#include <csignal>
|
|
extern "C" {
|
|
// not everyone has <cstdint>
|
|
#include <stdint.h>
|
|
}
|
|
#include <cstdio>
|
|
#include <sicktoolbox/SickLMS2xx.hh>
|
|
using namespace SickToolbox;
|
|
using namespace std;
|
|
|
|
bool got_ctrlc = false;
|
|
void ctrlc_handler(int)
|
|
{
|
|
got_ctrlc = true;
|
|
}
|
|
|
|
int main(int argc, char **argv)
|
|
{
|
|
if (argc != 3)
|
|
{
|
|
printf("Usage: print_scans DEVICE BAUD_RATE\n");
|
|
return 1;
|
|
}
|
|
string lms_dev = argv[1];
|
|
SickLMS2xx::sick_lms_2xx_baud_t desired_baud = SickLMS2xx::StringToSickBaud(argv[2]);
|
|
if (desired_baud == SickLMS2xx::SICK_BAUD_UNKNOWN)
|
|
{
|
|
printf("bad baud rate. must be one of {9600, 19200, 38400, 500000}\n");
|
|
return 1;
|
|
}
|
|
signal(SIGINT, ctrlc_handler);
|
|
uint32_t values[SickLMS2xx::SICK_MAX_NUM_MEASUREMENTS] = {0};
|
|
uint32_t num_values = 0;
|
|
SickLMS2xx sick_lms(lms_dev);
|
|
try
|
|
{
|
|
sick_lms.Initialize(desired_baud);
|
|
}
|
|
catch (...)
|
|
{
|
|
printf("initialize failed! are you using the correct device path?\n");
|
|
}
|
|
try
|
|
{
|
|
while (!got_ctrlc)
|
|
{
|
|
sick_lms.GetSickScan(values, num_values);
|
|
// print 12 ranges to the console
|
|
int inc = num_values / 11;
|
|
printf("%5d %5d %5d %5d %5d %5d %5d %5d %5d %5d %5d %5d\n",
|
|
values[0], values[inc],
|
|
values[2*inc], values[3*inc],
|
|
values[4*inc], values[5*inc],
|
|
values[6*inc], values[7*inc],
|
|
values[8*inc], values[9*inc],
|
|
values[10*inc], values[num_values-1]);
|
|
}
|
|
}
|
|
catch (...)
|
|
{
|
|
printf("woah! error!\n");
|
|
}
|
|
try
|
|
{
|
|
sick_lms.Uninitialize();
|
|
}
|
|
catch (...)
|
|
{
|
|
printf("error during uninitialize\n");
|
|
return 1;
|
|
}
|
|
printf("success.\n");
|
|
return 0;
|
|
}
|
|
|